BASi
30 produkt(ów)
-
Akcesoria elektrochemiczneAkcesoria do odtleniania
-
Elektrochemia – cele pomiaroweC3 Cell Stand
The C-3 Cell Stand is a Faraday cage with integrated magnetic stir plate and purge lines. It firmly holds BASi electrochemical cell components and enables remote stir and purge control via the software. The C-3 cell stand package is perfect for setting up a new lab for electrochemistry experiments b
-
Elektrochemia – cele pomiaroweCela BASi o małej objętości do stendu C-3
Most common cells for electrochemical analysis require sample volumes of 5-10 mL, but when rare or expensive materials are studied, a lower volume is desirable. A low-volume sample cell is available as an option for the C-3 Cell Stand.* It holds a minimum cell volume of 200 µL. The sample tube accom
-
Elektrochemia – cele pomiaroweCela do elektrolizy wyczerpującej
This cell is designed for the complete electrolysis of a solution species. Typical uses include determination of the number of electrons transferred per molecule, the absolute amount of an analyte, or electrosynthesis of a small amount (typically milligram quantities) of a new material. Components o
-
Elektrochemia – cele pomiaroweCela do pomiarów spektroelektrochemicznych
This cell is designed for the complete electrolysis of a solution species. Typical uses include determination of the number of electrons transferred per molecule, the absolute amount of an analyte, or electrosynthesis of a small amount (typically milligram quantities) of a new material. Components o
-
Elektrochemia – cele pomiaroweCela elektrochemiczna do badań korozji ASTM
The IP-U-1L-CCWJ is a fully equipped, vertically mounted, and ASTM G59-97 grade jacketed corrosion cell set-up that can be used with any Potentiostat / Galvanostat / Impedance Analyzer in the world. Dedicated sample holders are provided to hold a circular or flat coupons that can be easily mounted o
-
Elektrochemia – cele pomiaroweCela elektrochemiczna o małej objętości z płaszczem wodnym
Most common cells for electrochemical analysis require sample volumes of 5-10 mL, but when rare or expensive materials are studied, a lower volume is desirable. This water-jacketed low volume sample cell is available as an option for the C-3 Cell Stand*. It holds a minimum cell volume of 200 µL. The
-
Elektrochemia – cele pomiaroweCela fotoelektrochemiczna H-Cell
The IP-PECHC50 is a fully equipped, horizontally mounted and a dual compartment H-Cell set-up with an additional quartz window (light input port diameter: 20 mm) for studies in photo-based electrocatalysis such as Hydrogen Evolution Reaction (HER), Oxygen Evolution Reaction (OER), and more. The cons
-
Elektrochemia – cele pomiaroweCela z płaszczem wodnym do analizy wyczerpującej
This cell is designed for the complete electrolysis of a solution species. Typical uses include determination of the number of electrons transferred per molecule, the absolute amount of an analyte, or electrosynthesis of a small amount (typically milligram quantities) of a new material. The water-ja
-
Elektrochemia – cele pomiaroweCele pomiarowe
-
Elektrochemia – cele pomiaroweControlled Growth Mercury Electrode
Mercury drop working electrodes are invaluable for certain applications due to their high overpotential for hydrogen ion reduction and the high reproducibility of the electrode surface. Mercury drop electrodes are generated by the BASi® Controlled Growth Mercury Electrode (CGME) in three modes: DME
-
Akcesoria elektrochemiczneElektroda kalomelowa
This Hg2Cl2 (sat. KCl) reference electrode has a 6mm O.D. making it compatible with all BASi cell stands and cell tops.
-
Akcesoria elektrochemiczneElektrody chlorosrebrowe
-
Akcesoria elektrochemiczneElektrody niewodne Ag/AgCl
This kit contains the parts required for construction of a non-aqueous silver/silver ion reference electrode. The glass electrode body has a porous CoralPor™ tip attached with heat shrink tubing. The removable Teflon top contains a silver wire and 0.060 " gold-plated connecting pin for the cell lead
-
Akcesoria elektrochemiczneElektrody odniesienia
These compact, glass-bodied reference electrodes from BASi are available in two styles. The 7.5 cm long RE-5B reference electrode is used for electrochemistry experiments and is compatible with the C-3 Cell Stand , the CGME Controlled Growth Mercury Electrode Cell Stand , and the RDE-2 Rotating Disk
-
Akcesoria elektrochemiczneElektrody pomocnicze
Platinum wire auxiliary electrodes (0.5 mm diameter) are available in a variety of lengths. The electrode of choice depends upon the type of BASi® cell (and the experiment), as listed below. Each platinum wire terminates in a gold-plated brass connector. Electrical connection to this pin can be made
-
Akcesoria elektrochemiczneElektrody pracujące
These disk electrodes are small and easy to use. All are manufactured in a solvent-resistant PCTFE plastic body (7.5 cm length x 6 mm OD) which is embedded with highly polished disks of various electrode materials (glassy carbon, gold, platinum, palladium, nickel, or silver). There is also an electr
-
Akcesoria elektrochemiczneElektrody pracujące do elektrolizy wyczerpującej
A bulk electrolysis experiment (controlled potential coulometry) requires large surface area working electrodes in order to increase the rate of electrolysis. BASi® offers two such electrodes, a reticulated vitreous carbon (RVC) electrode and a platinum gauze electrode. The RVC electrode is the stan
-
Akcesoria elektrochemiczneElektrody przepływowe
BASi® working electrodes contain a cylinder of electrode material embedded in a PEEK block. The surface is polished to a mirror finish. The electrochemically active surface of the working electrode may be glassy carbon, gold, nickel, platinum, copper, or mercury/silver. Custom electrodes of non-list
-
Akcesoria elektrochemiczneLow Volume Cell For C-2 Cell Stand
-
Akcesoria elektrochemiczneMikroelektrody
Microelectrodes consist of small diameter metal wires or fibers (5-100 µm) sealed within tempered glass bodies. The flattened end of the microelectrode is polished to a mirror finish, which can be maintained using the polishing materials contained in the PK-4 Polishing Kit . The electrical connectio
-
Elektrochemia – cele pomiaroweRDE-2 Rotating Disk Electrode
The RDE-2 Cell Stand is a rotator system for rotating disk electrode experiments. It is capable of 50-10,000 rpm rotation rates and has an integrated gas purge function that can be controlled manually or remotely. The rotator unit is easily raised and lowered into the solution for electrochemistry e
-
Elektrochemia – cele pomiaroweStandardowa cela elektrochemiczna
This standard electrochemical cell is designed for use with BASi standard reference electrodes, standard working electrodes, and auxiliary electrodes. The glass cell comfortably holds a volume of around 100 mL and will allow you to test 25-75 mL of solution. It also comes with Teflon tubing for purg
-
Elektrochemia – cele pomiaroweStandardowa cela elektrochemiczna z płaszczem wodnym
This water-jacketed standard electrochemical cell is designed for use with BASi standard reference electrodes, standard working electrodes, and auxiliary electrodes. The water-jacketed glass cell comfortably holds a volume of around 100 mL and will allow you to test 25-75 mL of solution once electro
-
Elektrochemia – cele pomiaroweVC-2 Voltammetry Cell
The VC-2 Voltammetry Cell assembly ( MF-1052 ) can be used to hold the test sample and BASi® electrodes when a C-3 Cell Stand is not available. The Teflon ® top includes a platinum wire auxiliary electrode with gold connecting pin. This electrode can be removed and replaced if it becomes worn. BASi®
-
Elektrochemia – cele pomiaroweWieczka do cel pomiarowych BASi
-
Elektrochemia – cele pomiaroweZestaw H-Cell
The IP-HC-50 is a fully equipped, horizontally mounted and a dual compartment electrochemical H-Cell set-up for a wide variety of studies that require a separate compartment for counter and / or reference electrodes. The construction is gas-tight having two separate chambers, each equipped with gas
-
Akcesoria elektrochemiczneZestaw do czyszczenia elektrod
The electron transfer kinetics, and hence the current response, of redox-active species can be dramatically affected by the condition of the surface of the working electrode. Pretreatment of the electrode surface may therefore be necessary in order to obtain reproducible results. If rinsing the elec
-
Akcesoria elektrochemiczneZestaw do czyszczenia elektrod
-
Elektrochemia – cele pomiaroweZestaw z celą elektrochemiczną
The IP-PECUWC50 is a a fully equipped, horizontally mounted and a single compartment kit with an additional quartz window (light input port diameter: 20 mm), water recirculation coil and black acrylic box with lid for studies in photo-based electro-catalysis such as Hydrogen Evolution Reaction (HER)