Ivium-n-Stat

  • multi-channel Potentiostat/Galvanostat/ZRA
  • standard integrated impedance analyser in each channel: 10µHz – 250kHz (1 MHz optional)
  • 8 modules/16 channels per frame (stackable up to 64 channels)
  • Floating/grounded operation

Opis

Module* sModule
sModule
sModule
dModule dModule
System performance: 5A/10V 10A/5V 2A/20V 500mA/10V 2.5A/10V
Number of channels in module 1 1 1 2 2
Current compliance ±5A ±10A ±2A ±500mA ±2.5A
Maximum output voltage ±10V ±5V ±10V ±10V ±10V
Maximum compliance voltage ±10V ±5V ±20V ±10V ±10V
Peripheral port yes yes yes not available not available
*) all other specs same as standard model
Channel Performance: Standard sModule (2.5A/10V)
4 Electrodes WE, CE, RE and S
Current compliance ±2.5 A
Maximum output Voltage ±10 V
Potentiostat Bandwidth >500 kHz
Stability settings High Speed, Standard, and High Stability
Programmable response filter 1 MHz , 100 kHz , 10 kHz , 1 kHz , 10 Hz
Signal acquisition dual channel 16 bit ADC, 100.000 samples/sec
Potentiostat:
Applied potential range ±10 V, with 0.33 mV resolution
Applied potential accuracy 0.2%, or 2 mV
Current ranges ±10 nA to ±10 A in 10 steps
Measured current resolution 0.015% of current range, minimum 1.5 pA
Measured current accuracy 0.2%
Galvanostat
Applied current resolution 0.033% of applied current range
Applied current accuracy 0.2%
Potential ranges ±10mV, ±100mV, ±1V, ±10V
Measured potential resolution 0.003% of potential range, minimum 400nV
Measured potential accuracy 0.2%, or 2mV
Impedance Analyser
Frequency range 10µHz to 250kHz   (optional: 10µHz to 1MHz)
Amplitude 0.015mV to 1.0V, or 0.03% to 100% of current range
DC offset 16 bit dc offset subtraction, and 2 dc-decoupling filters
Electrometer
Input impedance >1000 Gohm //<8pF
Input bias current <10 pA
Bandwidth >5 MHz
Special functions:
Ohmic drop compensation 2 V/current range, 16 bits resolution
Peripheral connections: (not for dual channel module)
2 Analog in ±10 V, 16 bits resolution, bandwidth 40 kHz
1 Analog out ±10 V, 16 bits resolution
1 Digital input, and 3 Digital outputs 0 to +5 V
I-out, and E-out analog monitor for cell current and potential
AC-out ±0.5 V sinewave 10µHz-250kHz with variable attenuation
Channel-X, and Channel-Y inputs ±4 V: to record impedance from peripheral devices
Environment
Size w x d x h = 3 x 35 x 13 cm
Weight 0.7 kg
PC requirements Windows XP/7/8/10, with free USB port

The Ivium-n-Stat is controlled via Ivium’s own IviumSoft. This versatile, yet intuitive software, allows instrument control, data management and analysis, etc. IviumSoft can also interface with and be controlled from LabVIEWTM, C++, Delphi, etc. A full suite of IviumSoft is standard included with each instrument.

Ivium-n-Stat software conttrol:

– Control of separate channels individually
– All channels simultaneously
– Synchronous start
– Data from different channels plotted individually or in 1 single graph