Wszystkie produkty
73 produktów w ofercie.
-
BASiAkcesoria do odtleniania
-
CH InstrumentsBipotencjostaty serii CHI700F
-
BASiC3 Cell Stand
The C-3 Cell Stand is a Faraday cage with integrated magnetic stir plate and purge lines. It firmly holds BASi electrochemical cell components and enables remote stir and purge control via the software. The C-3 cell stand package is perfect for setting up a new lab for electrochemistry experiments b
-
BASiCela BASi o małej objętości do stendu C-3
Most common cells for electrochemical analysis require sample volumes of 5-10 mL, but when rare or expensive materials are studied, a lower volume is desirable. A low-volume sample cell is available as an option for the C-3 Cell Stand.* It holds a minimum cell volume of 200 µL. The sample tube accom
-
BASiCela do elektrolizy wyczerpującej
This cell is designed for the complete electrolysis of a solution species. Typical uses include determination of the number of electrons transferred per molecule, the absolute amount of an analyte, or electrosynthesis of a small amount (typically milligram quantities) of a new material. Components o
-
BASiCela do pomiarów spektroelektrochemicznych
This cell is designed for the complete electrolysis of a solution species. Typical uses include determination of the number of electrons transferred per molecule, the absolute amount of an analyte, or electrosynthesis of a small amount (typically milligram quantities) of a new material. Components o
-
BASiCela elektrochemiczna do badań korozji ASTM
The IP-U-1L-CCWJ is a fully equipped, vertically mounted, and ASTM G59-97 grade jacketed corrosion cell set-up that can be used with any Potentiostat / Galvanostat / Impedance Analyzer in the world. Dedicated sample holders are provided to hold a circular or flat coupons that can be easily mounted o
-
BASiCela elektrochemiczna o małej objętości z płaszczem wodnym
Most common cells for electrochemical analysis require sample volumes of 5-10 mL, but when rare or expensive materials are studied, a lower volume is desirable. This water-jacketed low volume sample cell is available as an option for the C-3 Cell Stand*. It holds a minimum cell volume of 200 µL. The
-
BASiCela fotoelektrochemiczna H-Cell
The IP-PECHC50 is a fully equipped, horizontally mounted and a dual compartment H-Cell set-up with an additional quartz window (light input port diameter: 20 mm) for studies in photo-based electrocatalysis such as Hydrogen Evolution Reaction (HER), Oxygen Evolution Reaction (OER), and more. The cons
-
BASiCela z płaszczem wodnym do analizy wyczerpującej
This cell is designed for the complete electrolysis of a solution species. Typical uses include determination of the number of electrons transferred per molecule, the absolute amount of an analyte, or electrosynthesis of a small amount (typically milligram quantities) of a new material. The water-ja
-
BASiCele pomiarowe
-
PalmSensConnection terminal for use with MUX8-R2
-
BASiControlled Growth Mercury Electrode
Mercury drop working electrodes are invaluable for certain applications due to their high overpotential for hydrogen ion reduction and the high reproducibility of the electrode surface. Mercury drop electrodes are generated by the BASi® Controlled Growth Mercury Electrode (CGME) in three modes: DME
-
PalmSensDifferential Electrometer Amplifier
-
Dydaktyczne ogniwo paliwowe
Niskotemperaturowe ogniwo paliwowe zasilane wodorem przeznaczone do celów dydaktycznych w szkołach oraz uczelniach wyższych.
-
PalmSensEducational Kit
The PalmSens Educational Kit it is designed as the foundation for an electrochemistry course , lab class or similar teaching events. Contents The Educational kit contains: 20x ItalSens Graphite Sensors 20x ItalSens Sensors for Heavy Metals 20x BVT Gold Sensors 1x 2 mm diameter Platinum Working Elect
-
BASiElektroda kalomelowa
This Hg2Cl2 (sat. KCl) reference electrode has a 6mm O.D. making it compatible with all BASi cell stands and cell tops.
-
BASiElektrody chlorosrebrowe
-
BASiElektrody niewodne Ag/AgCl
This kit contains the parts required for construction of a non-aqueous silver/silver ion reference electrode. The glass electrode body has a porous CoralPor™ tip attached with heat shrink tubing. The removable Teflon top contains a silver wire and 0.060 " gold-plated connecting pin for the cell lead
-
BASiElektrody odniesienia
These compact, glass-bodied reference electrodes from BASi are available in two styles. The 7.5 cm long RE-5B reference electrode is used for electrochemistry experiments and is compatible with the C-3 Cell Stand , the CGME Controlled Growth Mercury Electrode Cell Stand , and the RDE-2 Rotating Disk
-
BASiElektrody pomocnicze
Platinum wire auxiliary electrodes (0.5 mm diameter) are available in a variety of lengths. The electrode of choice depends upon the type of BASi® cell (and the experiment), as listed below. Each platinum wire terminates in a gold-plated brass connector. Electrical connection to this pin can be made
-
BASiElektrody pracujące
These disk electrodes are small and easy to use. All are manufactured in a solvent-resistant PCTFE plastic body (7.5 cm length x 6 mm OD) which is embedded with highly polished disks of various electrode materials (glassy carbon, gold, platinum, palladium, nickel, or silver). There is also an electr
-
BASiElektrody pracujące do elektrolizy wyczerpującej
A bulk electrolysis experiment (controlled potential coulometry) requires large surface area working electrodes in order to increase the rate of electrolysis. BASi® offers two such electrodes, a reticulated vitreous carbon (RVC) electrode and a platinum gauze electrode. The RVC electrode is the stan
-
BASiElektrody przepływowe
BASi® working electrodes contain a cylinder of electrode material embedded in a PEEK block. The surface is polished to a mirror finish. The electrochemically active surface of the working electrode may be glassy carbon, gold, nickel, platinum, copper, or mercury/silver. Custom electrodes of non-list
-
PalmSensEmStat3 Blue
EmStat3 Blue Small and wireless potentiostat USB or Wireless Bluetooth connection Potential range ±3 V or ±4 V Current ranges 1 nA to 10 mA or 100 mA Ideal for mobile sensor applications
-
PalmSensEmStat4 MUX
EmStat4 MUX 2-in-1: Potentiostat with integrated multiplexer Integrated 8-channel multiplexer Supports 2-, 3- and 4-electrode setup using Sense Lead Potential range: ± 3V Compliance voltage: ± 5V Current ranges: 1 nA – 10 mA Maximum current: ± 30 mA FRA / EIS up to 200 kHz
-
PalmSensEmStat4R
EmStat4R Ruggedized potentiostat with battery & Bluetooth Portable: battery, Bluetooth and rugged housing Available with connection module for sensor cable or SPE Potential range ±3 V Max. current ±30 mA Optional impedance analyzer: 10 μHz up to 200 kHz
-
PalmSensEmStat4R
EmStat4R Ruggedized potentiostat with battery & Bluetooth Portable: battery, Bluetooth and rugged housing Available with connection module for sensor cable or SPE Potential range ±3 V Max. current ±30 mA Optional impedance analyzer: 10 μHz up to 200 kHz
-
PalmSensEmStat4S
EmStat Blue is a small and low cost potentiostat with research grade capabilities. It has eight current ranges from 1 nA to 100 mA (EmStat3+ Blue) full scale, with a minimum resolution of 1 pA. It provides the most relevant electroanalytical measurement techniques and is used with the PSTrace softwa
-
PalmSensEmStat4T
Tailored electrochemistry through touch-controlled apps • ±3 V applied potential range • ±30 mA max. current • Supports common electrochemical techniques • Standalone operation with MethodSCRIPT • or remotely controlled by laptop or phone • Bar/QR-code scanner • Customizable cell interface with droplet-detection for SPEs
-
PalmSensEmStat4X
EmStat4X High performance in a small footprint Potential range ±3 V or ±6 V Max. current ±30 mA or ±200 mA Wireless control Extendable with multiplexer iR compensation
-
PalmSensEmStatMUX8-R2
USB powered potentiostat with integrated multiplexer potentiostat with integrated 8 channel multiplexer potential range: ± 3V or ± 4V compliance voltage: ± 5V or ± 8V current ranges: 1 nA – 100 mA
-
Forma do wycinania membran i uszczelek do ogniw paliwowych
Precyzyjne formy do właściwego przygotowania elektrod, membran i uszczelek do zastosowania w ogniwach paliwowych.
-
PalmSensGalvanic Isolation Dongle
-
PalmSensHigh-density sensor cable for use with MUX8-R2
-
PalmSensLM35 Temperature Sensor
-
BASiLow Volume Cell For C-2 Cell Stand
-
PalmSensMUX16
Multiplexer for 16 cells Automatically switch between electrochemical cells 3 different electrode or sensor configurations Switches up to 16 working electrodes, CE and RE are not switched
-
PalmSensMUX8-R2
Multiplexer for 8 cells Automatically switch between electrochemical cells Easy stacking with magnetic feed and top 4 different electrode or sensor configurations Daisy chain multiplexers, up to 128 channels!
-
PalmSensMagnetic Stirrer with Switchbox (EmStat Blue)
-
BASiMikroelektrody
Microelectrodes consist of small diameter metal wires or fibers (5-100 µm) sealed within tempered glass bodies. The flattened end of the microelectrode is polished to a mirror finish, which can be maintained using the polishing materials contained in the PK-4 Polishing Kit . The electrical connectio
-
CH InstrumentsMikrowagi EQCM serii CHI400C
-
PalmSensMultiEmStat4
No Compromises on Productivity and Performance The MultiEmStat4 is a compact Potentiostat, Galvanostat, and optional Frequency Response Analyser (FRA) for Electrochemical Impedance Spectroscopy (EIS) with 8 or 12 channels. The MultiEmStat4 comes in two versions; the Low Range version is great for ap
-
PalmSensMultiPalmSens4
The MultiPalmSens4 is a flexible multi-channel potentiostat, galvanostat and impedance analyzer which you can fully tailor to your requirements and budget. The MultiTrace software allows for using each channel individually or simultaneously or running a sequence of automated tasks on each channel. E
-
CH InstrumentsMultipotencjostaty serii CHI1000D
-
CH InstrumentsMultipotencjostaty serii CHI1400
-
PalmSensNexus
Nexus Engineered for Electrochemical Excellence (Bi)Potentiostat/ Galvanostat/ Impedance analyzer FRA / EIS: 10 μHz up to 1 MHz 11 current ranges: 100 pA to 1 A Dual EIS with second sense electrode Script your experiments using MethodSCRIPT Use with PSTrace software for Windows
-
Niskotemperaturowe ogniwo paliwowe
Ogniwo przeznaczone jest do zastosowań badawczych i rozwojowych w dziedzinie niskotemperaturowych ogniw paliwowych z membraną polimerową.
-
PalmSensPalmSens4
The PalmSens4, is a USB and battery powered Potentiostat, Galvanostat, and optional a Frequency Response Analyser (FRA) for Electrochemical Impedance Spectroscopy (EIS). The PalmSens4 has a large potential range (-5V to 5V or -10V to 10V) and current range (100 pA to 10 mA) with a high resolution an
-
CH InstrumentsPotencjostaty/Galwanostaty serii CHI1100D
-
CH InstrumentsPotencjostaty/Galwanostaty serii CHI600F
-
CH InstrumentsPrzenośne potencjostaty/bipotencjostaty serii CHI1200C
-
CH InstrumentsPrzenośne potencjostaty/bipotencjostaty serii CHI1200C
-
Płytka monopolarna do ogniw paliwowych
Płytki mono- i bipolarne do ogniw i stosów ogniw paliwowych. Wykonane zostały z najwyższej jakości grafitu japońskiej firmy Toyo Tanso.
-
BASiRDE-2 Rotating Disk Electrode
The RDE-2 Cell Stand is a rotator system for rotating disk electrode experiments. It is capable of 50-10,000 rpm rotation rates and has an integrated gas purge function that can be controlled manually or remotely. The rotator unit is easily raised and lowered into the solution for electrochemistry e
-
PalmSensRackMount 16CH
RackMount 16CH 16-channel potentiostat / galvanostat / EIS analyzer Desktop or 19 inch rack-ready housing Embedded Lablink Hub FRA / EIS: 10 µHz up to 200 kHz Potential range: ±3 V Max. current: ±30 mA
-
PalmSensSPE Connector (4 pins LEMO)
-
PalmSensSPE adapter for use with MUX8-R2 Multiplexer
-
PalmSensScreen printed electrodes
This part of the catalog contains all thick film and thin film electrodes. Many of these electrodes can be used as disposable, some are also suitable for multiple use. If you are looking for electrochemical cells, please have a look at our Accessories section. Screen printed electrodes - strona prod
-
PalmSensSensit Smart
The Sensit Smart is the world smallest ready-to-go potentiostat available on the market. The Sensit Smart can be directly inserted in a smartphone or tablet and controlled via the Android app PStouch . You can use the USB-C Female to USB-A cable to connect the Sensit Smart to a classic USB port on y
-
PalmSensSensit Wearable
Sensit Wearable Potentiostat for wearable biosensors Accelerate the development of your wearable sensor Works wireless and autonomous, battery powered Measure up to two different analytes using two working electrodes Use with PSTrace software for Windows Smooth start with the development kit
-
PalmSensSensitBT
The Sensit BT is ideal for electrochemical sensor applicatons. The Sensit BT connects via Bluetooth to your smartphone or tablet and controlled via the Android app PStouch . You can use the USB-C port to charge the Sensit BT or connect to a classic USB port on your PC and control the Sensit BT via o
-
PalmSensSensor cable with banana connectors for use with MUX8-R2
-
Silikonowe grzałki samoprzylepne
Najwyższej jakości silikonowe grzałki samoprzylepne, o różnej mocy dostosowane do różnych napięć zasilających (230V AC, 110V AC, 24V DC). Dostępne są w dowolnych rozmiarach. Idealne do stabilizacji temperatury ogniw paliwowych i innych urządzeń laboratoryjnych.
-
BASiStandardowa cela elektrochemiczna
This standard electrochemical cell is designed for use with BASi standard reference electrodes, standard working electrodes, and auxiliary electrodes. The glass cell comfortably holds a volume of around 100 mL and will allow you to test 25-75 mL of solution. It also comes with Teflon tubing for purg
-
BASiStandardowa cela elektrochemiczna z płaszczem wodnym
This water-jacketed standard electrochemical cell is designed for use with BASi standard reference electrodes, standard working electrodes, and auxiliary electrodes. The water-jacketed glass cell comfortably holds a volume of around 100 mL and will allow you to test 25-75 mL of solution once electro
-
BASiVC-2 Voltammetry Cell
The VC-2 Voltammetry Cell assembly ( MF-1052 ) can be used to hold the test sample and BASi® electrodes when a C-3 Cell Stand is not available. The Teflon ® top includes a platinum wire auxiliary electrode with gold connecting pin. This electrode can be removed and replaced if it becomes worn. BASi®
-
BASiWieczka do cel pomiarowych BASi
-
BASiZestaw H-Cell
The IP-HC-50 is a fully equipped, horizontally mounted and a dual compartment electrochemical H-Cell set-up for a wide variety of studies that require a separate compartment for counter and / or reference electrodes. The construction is gas-tight having two separate chambers, each equipped with gas
-
BASiZestaw do czyszczenia elektrod
The electron transfer kinetics, and hence the current response, of redox-active species can be dramatically affected by the condition of the surface of the working electrode. Pretreatment of the electrode surface may therefore be necessary in order to obtain reproducible results. If rinsing the elec
-
BASiZestaw do czyszczenia elektrod
-
BASiZestaw z celą elektrochemiczną
The IP-PECUWC50 is a a fully equipped, horizontally mounted and a single compartment kit with an additional quartz window (light input port diameter: 20 mm), water recirculation coil and black acrylic box with lid for studies in photo-based electro-catalysis such as Hydrogen Evolution Reaction (HER)
-
Zestawy edukacyjne
Zestaw edukacyjny PalmSens został zaprojektowany jako podstawa do prowadzenia kursów oraz zajęć laboratoryjnych z elektrochemii.